Page 40 P/N: 49211C © 2002 Detection Systems, Inc. All rights reserved. DS7240/DS7220 User's Guide
PART II: KEYPAD USER’S GUIDE: DS7445i LED KEYPAD
5.19 Check System Troubles
Key Sequence: [#] + [4]
Description
Your system emits a trouble tone to alert you to a
system trouble event. Things such as low batteries
cause system troubles. Use this function to learn what
is causing the trouble and what steps to take to
correct it.
The system may be on or off when a system trouble
occurs. If the system is on, you must turn it off to
check the trouble.
The trouble tone for AC Failure events sounds
at all keypads in all areas. However, the
trouble tone must be silenced in each area
(silencing the trouble tone in one area does
not silence it in the other areas).
Procedure
1. When a system trouble occurs, the Power LED
flashes slowly, the Trouble LED turns on and the
keypad sounds the trouble tone (if programmed).
Enter [#] + [4] to silence the trouble tone and view
the specific trouble.
On
Status
Fire
Supervisory
Bell Silenced
TEST WEEKLY
1 2 3 4 5 6 7 8
9 10 11 12
13 14
15 16
Power LED flashes slowly
PerimeterArmed
Trouble LED turns ON
Trouble
Power
2. The keypad displays system troubles by turning
on assigned Zone LEDs. See Table 11 to
determine which system trouble has occurred
based on the LED that has turned on.
Zone LED Description
1 Weekly Test Due: This prompts you to conduct
your weekly system test. See “System Test” on
page 41.
2 System Trouble: Press [2] to determine the
specific trouble. See “View System Trouble” on
page 40.
3 Remote Program Session Active: Your
Security Company is currently connected to your
system via the telephone line.
5
Date and Time Lost: Press [5] to set the date
and time.
6 Running on Battery Only: The power to your
system has been disconnected or has failed.
8 Zone Trouble: Press [8] to determine which
zone trouble occurring. See “View Zone Trouble”
on page 41.
10 Alarm Memory: Press [0] to view previous
alarms that occurred.
Table 11: Checking System Troubles
3. Press the [#] key to exit this function.
If Trouble messages persist, contact your
Security Company for assistance.
5.20 View Alarm Memory
I can perform this function.
I cannot perform this function.
Key Sequence: [#] + [4] + [0]
Description
After an alarm has been silenced and cleared from
the display, you may still review the zones that had
been in alarm.
Procedure
1. Make sure that the system is turned off (Armed
LED is off).
2. Enter a valid user PIN.
3. Enter [#] + [4] + [0].
The keypad displays all zones that are in alarm
memory.
If the zone LED is flashing fast, the zone is
currently in alarm, or was in alarm.
If the zone LED is flashing slowly, the alarm
was aborted. No reports for the alarm event
were sent to the Security Company.
5.21 View System Trouble
I can perform this function.
I cannot perform this function.
Key Sequence: [#] + [4] + [2]
Description
Use this function to view system trouble events. A
system trouble condition may occur if there is a
communications trouble, or if it is time for the system
to be serviced by your Security Company.
Procedure
1. Make sure that the system is turned off (Armed
LED is off).
2. Enter a valid user PIN.
3. Enter [#] + [4] + [2].
The keypad displays current system trouble
events by turning on or flashing the zone LEDs.