Bosch AMAX panel 4000 EN Guia de Instalação Página 53

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
Vista de página 52
Refer to Section Keypad Indicators, page 20 to see how the zone is displayed during
exit time.
18 - Technical Alarm
The Technical Alarm zone will perform as below:
1. Disarm:
Zone normal - no Alarm / no report
Zone triggered - Alarm / report
2. AWAY Arm:
Zone normal - no Alarm / no report
Zone triggered - Alarm / report
Zone triggered - during exit time - Alarm / report
Zone triggered - during entry time - Alarm / report
3. STAY Arm: Same as AWAY Arm performance.
A Technical zone does not send a restore report until the zone is restored.
19 - Reset
The Reset zone will perform as below:
1. Disarm:
Zone normal - no Alarm / no report
Zone triggered – performs system reset / no report
2. AWAY Arm:
Zone normal - no Alarm / no report
3. STAY Arm: Same as AWAY Arm performance.
20 - Instant Report
The Instant report zone will perform as below:
1. Disarm:
Zone normal - no Alarm / no restore report
Zone triggered - no Alarm / no report
2. AWAY Arm:
Zone normal - no Alarm / no restore report
Zone triggered - no Alarm / sends report
Zone triggered - during exit time - Alarm / sends report
Zone triggered - during entry time - Alarm / sends report
3. STAY Arm: Same as AWAY Arm performance.
Zone Function Settings / Zone Options
Zone Function Option Description
Force Arm / Bypass 0 Disabled
1 Force Arm
2 Bypass
3 All
Silent Alarm / Chime
Mode
0 Disabled
1 Silent Alarm
7.2.3
AMAX panel 4000 / AMAX panel 4000
EN
Settings | en 53
Bosch Sicherheitsysteme GmbH Installation Guide 2013.07 | 03 | F.01U.267.112
Vista de página 52
1 2 ... 48 49 50 51 52 53 54 55 56 57 58 ... 175 176

Comentários a estes Manuais

Sem comentários