Bosch DCN Next Generation Manual do Utilizador Página 60

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 296
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 59
DCN Next Generation Open Interface Release 2.4 Config Install and Database
en | 60
Bosch Communications Systems | 2007 February | SRS_SCSIINF | Du010934
Availability
This function is available in CCU system modes config, congress and maintenance.
Parameter structure for the function
The function has no input parameters.
Response structure from the function
The function has no response parameters.
Error codes returned
SI_E_NOERROR
SI_E_NO_UNITS_FOUND
5.11 SI_C_REQ_OPERATION_MODE
Purpose
Request the operation mode of all units in the parameter list. After executing this function, a
notification will be send for each known unit.
Availability
This function is available in system mode: CONFIG.
Parameter structure for the function
This function requires the structure SI_T_SERIALNR_LIST as parameter. This structure is
defined in section xxx.
Response structure from the function
The function has no response parameters.
Error codes returned
SI_E_NOERROR
Related functions
SI_C_SET_OPERATION_MODE
Update notifications
SI_C_OPERATION_MODE
5.12 SI_C_SET_OPERATION_MODE
Purpose
Set the operation mode of the unit.
Availability
This function is available in system mode: CONFIG.
Parameter structure for the function
The function requires the following structure as parameter:
typedef struct
{
DWORD dwSerialNr;
BYTE byMode;
} SI_T_OPERATION_MODE;
where:
dwSerialNr The serial number of a unit
byMode The operation mode of the unit which is one of the following:
SI_C_OPERATION_MODE_MULTI
SI_C_OPERATION_MODE_SINGLE
Response structure from the function
The function has no response parameters.
Error codes returned
SI_E_NOERROR
SI_E_WRONG_PARAMETER
SI_E_NOT_CONTROL_UNIT