DCN Next Generation Open Interface Release 2.4 Config Install and Database
en | 52
Bosch Communications Systems | 2007 February | SRS_SCSIINF | Du010934
Event Update Notification Continue with remote function
and a few seconds later for
every unit connected to that
Slave CCU separately
SC_C_CONNECT_UNIT
the unit connect updates:
SI_C_START_INSTALL and run
installation as described in
example-2 in Appendix C
Switch On another
Single-Mode CCU
<None>
Switch Off a Slave
CCU
SC_C_DISCONNECT_SLAVE_CCU
Switch Off another
Single-Mode CCU
<None>
Connect a unit to
CCU-A.
<None>
Disconnect a unit
from CCU-A.
<None>
Connect a unit to a
Slave CCU.
SC_C_CONNECT_UNIT
Recommended before continuing:
SI_C_START_INSTALL and run
installation as described in
example-2 in Appendix C
Disconnect a unit
from a Slave CCU.
SC_C_DISCONNECT_UNIT
Connect a unit to
another Single-Mode
CCU.
<None>
Disconnect a unit
from another Single-
Mode CCU.
<None>
4.2 SC_C_CCU_REBOOT
Purpose
Notifies the remote controller that the CCU has restarted. This notification is always send at
start-up of the CCU and is the only notification message send by the CCU till the update
request function SC_C_START_APP is executed.
This notification should be monitored to detect a restart of the CCU. The remote controller
should take appropriate actions to restore the settings.
Notify structure with this update
The update comes with the same structure as used for the response of the remote function
SC_C_GET_CCU_VERSIONINFO (section 3.5).
4.3 SC_C_CONNECT_UNIT
Purpose
Notifies the remote controller that a new unit has connected to the CCU. The remote
controller can use this notification to add this unit to its functionality.
Notify structure with this update
The update uses the following structure:
SC_T_UNIT_DATA tUnitData;
where:
tUnitData Information about the unit that is connected. The elements
present in the structure are defined in section 3.6.
Comentários a estes Manuais