The protocol for port 2 can be set by setting Dip-Switches 5+6 as shown in the following
table:
Switch Protocol Remark
5 6
off off Simple
The serial port is used with the ‘Simple’ feature protocol
as described in §4.1.3.
off on Terminal The serial port is used with an ASCII interface. Expected is
a terminal to do diagnostics on the CCU.
on off Full
The serial port is used with the ‘Full’ feature protocol as
described in §4.1.2.
on on Camera control The serial port is used for connection to an Allegiant Video
Switcher (AVS) or AutoDome camera (DCC). (Default)
Note that it is possible to select the ‘Full’ feature protocol on both ports. This is however not
recommended due to processing power and memory limitations.
A.2. TCP/IP port setting MCCU-Master (DCN-NCO)
The TCP/IP port number used for the communication between the NCO and the remote
controller is fixed set to the following value:
Tcp/Ip Port number 9451 Dune Open Interface protocol port