3. Controller Functions
Para-Getriebeumschalt
Parameter protocol!
Parameter
P14
A20
Designation
G-CHANGE
OSCI RPM
Function
allocation of
parameter record
to a gear stage
oscillation speed for gear changeover
Value range or value
< 0 >
< 1 >
< 2 >
1 to 200
S R Q
(1/min)
- none
- stage 1
- stage 2
Note:
Gear stages 1 and 2 must each be assigned at least once to a parameter
record by parameter values 1 and 2 in the G-CHANGE parameters.
When changing from a parameter record with assigned gear stage to a
parameter record that is not assigned to any gear stage, the previous
gear stage remains coupled.
The switchable parameter records enable the drive to be optimized
according to the gear stages (see section 3.14).
Figure 74: Parameter for gear change via the controller
Gear stage dependent drive
optimization