• DOK-DIAX01-MAIN+2AD+1M-ANW1-EN-E1,44 • 07.97
63
3. Controller Functions
Para
-
Drehz
-
Fkt
Parameter protocol!
☞
Parameter
P07
P08
P09
P10
P11
A03
A05
P16
M03
Designation
P-GAIN 1
I-GAIN 1
GAIN RPM
P-GAIN 2
I-GAIN 2
MIN RPM
FUNCT 1
PQ FUNCT
T-FILTER
Value range or value
0.....20.00
0.....20.00
0.....9999
0.....9.99
0.....9.999
1.....999
< 16 >
< 4 >
0.....3
S R Q
S R Q
S R Q
S R Q
S R Q
S R Q
(1/min)
(1/min)
Function
P-gain of the speed controller below switching speed
I-gain of the speed controller below switching speed
switching speed from P-I-Gain1 to P-I-Gain2
P-gain of the speed controller above switching speed
I-gain of the speed controller above switching speed
speed limit
general switch off of I-gain of the speed controller
at N
command
below MINRPM
parameter-dependent switch off of I-gain of the
speed controller at Ncommand below MINRPM
time constant value of the tachometer filter
Speed dependent
changeovers
Braking without overshoot
Figure 48: Parameter for speed controller functions
Changeover from P-I-GAIN 1 into P-I-GAIN 2 is automatic if the speed
of the motor is below the value of GAIN RPM.
The drive automatically switches to P-GAIN 2 and I-GAIN 2 at the speed
in parameter I-U-RPM (M09), even if GAIN RPM was set higher!
For braking without overshoot, for a speed command value of less than
MINRPM, the drive can be switched to pure P-control. This is always
achieved with the FUNCT 1 parameter (A parameter), but only with the
PQ FUNCT parameter (PQRS parameter) in the respective, active
parameter record.
The drive can also be run with true P or I control (value 0 is set for the other
respective parameter).
Vista de página 62
1 2 ... 58 59 60 61 62 63 64 65 66 67 68 ... 145 146

Comentários a estes Manuais

Sem comentários

Danfoss VLT HVAC Basic Drive FC 101 manuali

Manuali dei proprietari e guide per l'utente per Protezione antincendio Danfoss VLT HVAC Basic Drive FC 101.
We fornisce 1 manuali pdf Danfoss VLT HVAC Basic Drive FC 101 per scaricare gratuitamente in base al tipo di documento: Informazioni Techniche


Indice

Programming Guide

1

1 Introduction

2

3 Parameters

2

Contents

2

2 MG.18.B1.02 - VLT

3

4 Troubleshooting

4

5 Parameter Lists

4

4 MG.18.B1.02 - VLT

5

1.1.2 Symbols

7

1.1.3 Abbreviations

7

Definitions

8

175ZA078.10

9

Pull-out

9

MG.18.B1.02 - VLT

10

High Voltage

11

1.1.6 Electrical Overview

12

2 How to Programme

13

14 MG.18.B1.02 - VLT

15

Closed Loop Set-up Wizard

17

Main Menu

19

* English

21

* Interna

21

* Active Set

22

3.1.3 0-3* LCP Custom Readout

23

3.1.4 0-4* LCP

24

3.1.5 0-5* Copy / Save

24

3.1.6 0-6* Password

24

* Variable

25

* [0.01 - 26.0

26

* [100.0

26

* Off No function

26

3.2.3 1-3* Adv. Motor Data

27

1-4* Cable Length

27

3.2.7 1-7* Start Adjustments

28

3.2.8 1-8* Stop Adjustments

29

3.2.9 1-9* Motor Temperature

29

3.4.1 3-0* Reference Limits

31

3.4.2 3-1* References

31

* Analog in 54

32

* Local bus

32

* [0.05

32

3.4.5 3-8* Other Ramps

33

3.5.1 4-1* Motor Limits

34

3.5.2 4-5* Adj. Warnings

34

3.5.3 4-6* Speed Bypass

35

3.6.1 5-0* Digital I/O Mode

36

3.6.2 5-1* Digital Inputs

36

* No operation

38

* Coast inverse

38

3.6.3 5-4* Relays

39

5-40 Function Relay

40

Option: Function:

40

3.6.4 5-9* Bus Controlled

41

3.7.1 6-0* Analog I/O Mode

42

3.7.2 6-1* Analog Input 53

42

3.7.3 6-2* Analog Input 54

43

* [0.0 - 200.0

44

* [0.0 - 100.0 %]

44

* 0-20 mA

45

Options - Group 8

47

3.8.1 8-0* General Settings

47

3.8.2 8-3* FC Port Settings

47

3.8.3 8-5* Digital/Bus

48

3.8.4 8-7* BACnet

49

3.8.6 8-9* Bus Feedback

50

3.9.1 13-** Prog. Features

51

13-0* SLC Settings

51

* Do not reset

53

* Disabled

53

* [-9999.0

54

* [0.0

54

13-52 SL Controller Action

58

* Manual reset

59

3.10.4 14-4*Energy Optimising

60

3.10.5 14-5* Environment

60

* [1.0 - 16.0 kHz]

61

3.11.1 15-0* Operating Data

62

3.11.2 15-3* Alarm Log

62

3.12.1 16-0* General Status

64

3.12.2 16-1* Motor Status

64

3.12.3 16-3* Drive Status

65

* [0.1 - 9999.0

69

* [0.0 - 400.0 %]

69

* [0.0 - 400.0 Hz]

70

* [0.0 - 100.0

70

Group 24

72

3.16.1 24-0* Fire Mode

72

Range: Function:

74

4.1.1 Alarm Words

77

4.1.2 Warning Words

77

4.1.3 Extended Status Words

78

4.1.4 Fault Messages

78

78 MG.18.B1.02 - VLT

79

5.1.3 1-** Load and Motor

83

5.1.4 2-** Brakes

84

5.1.5 3-** Reference/Ramps

84

5.1.6 4-** Limits/Warnings

85

5.1.7 5-** Digital In/Out

85

5.1.8 6-** Analog In/Out

86

5.1.9 8-** Comm. and Options

87

5.1.10 13-** Smart Logic

88

5.1.13 16-** Data Readouts

90

5.1.16 22-** Appl. Functions

91

92 MG.18.B1.02 - VLT

93

94 MG.18.B1.02 - VLT

95

96 MG.18.B1.02 - VLT

97

*MG18B102*

98