Bosch Solution 16plus Especificações Página 31

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 44
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 30
PET Pager/SMS Reporting
The system can be configured by your security company to report to your mobile phone via
SMS messaging or a pocket pager when an alarm and/or any system event occurs. When
using either of these two reporting formats, easy to understand text messages will be
received so that the appropriate action can be taken.
The following table list all the events that can be reported in SMS messaging and PET pager
formats.
Event At Control Panel PET/SMS Message
AC Fail AC Fail
AC Restore AC restore
Area Has Been Armed Close Area #, User #
Area Has Been Disarmed Open Area #, User #
Burglary Zone Has Triggered Alarm Zone #
Burglary Zone Has Restored Restore Zone #
Burglary Zone Triggered, Area # Alarm Zone #, Area #
Burglary Zone Restored, Area # Restore Zone #, Area #
Access Denied – Codepad Tamper Codepad Tamper
Data Programming Change Data Change
System Is Armed Close User #
System Is Disarmed Open User #
Codepad Duress Duress, Open User #
Low Battery Low Battery
Low Battery Restore Battery Restore
Codepad Panic Alarm Panic
Codepad Fire Alarm (V1.37+) Fire
Codepad Medical Alarm (V1.37+) Medical
Test Report Test
Zone Automatically Isolated When Armed Bypass Zone #
Disarming When Zone Has Been Isolated Bypass Restore Zone #
Zone Unsealed At End Of Exit Time Trouble Zone #
Zone Has Restored After Exit Time Trouble Restore #
24 Hour Zone Triggered 24 Hour Alarm #
24 Hour Zone Restored 24 Hour Restore #
24 Hour Fire Zone Triggered Fire Zone #
24 Hour Fire Zone Restored Fire Restore #
Table 11: PET Pager/SMS Messages
The # symbol represents the zone or area number in the transmission.
The following example shows how a single transmission will be received on the PET pager
or mobile phone using SMS messaging. A similar message to the one below will be seen
when the control panel is armed by User 1.
1111 CLOSE USER 01
Subscriber ID Number System Armed User #1
The Subscriber ID number is a unique 4 digit number identifying which alarm system has
made the call. Only your security company can program the Subscriber ID number (Factory
Default = 0000).
!"#$%&"'()* Operators Manual 31
Electronics Design and Manufacturing Pty Limited ISSUE160.DOC
Vista de página 30