Remote reports on VLine? - Y or N: Allows the operator to specify the Line number reference for reporting Radio
Communicator messages to the Automation software. Radio Communicator reports are all events reported by the
SAFECOM Radio Communicator to the SC9000 via radio. Radio Communicator messages do not include Alarm
messages from an Alarm Panel Dialer. “YES” = Radio Communicator messages will be sent to the Automation
software using the VLine field from the Remote Setup Menu #1. “NO” = Radio Communicator messages will be sent
to the Automation software using Line # 0. Alarm messages from an Alarm Panel Dialer are always reported to the
Automation software using the VLine field from the Radio Communicator account Setup Menu #1.
Digital reports on VAccount? - Y or N: Allows the operator to specify the Account number reference for reporting
Alarm Panel Dialer (alarm signal) messages to the Automation software. Digital reports are Alarm signals from an
Alarm Panel Dialer that are reported by the SAFECOM Radio Communicator to the SC9000 via the SAFECOM
network. “YES” = Alarm Panel Dialer messages will be sent to the Automation software using the Account # entered
on the VAccount field from the Radio Communicator account Setup Menu #1. “NO” = Radio Communicator messages
will be sent to the Automation software using the Alarm Panel Account number (programmed by the installer at time
of Alarm Panel installation). Radio Communicator messages are always reported to the Automation software using
the VAccount field from the Radio Communicator account Setup Menu #1.
Report Dialer Errors? - Y or N: Allows the operator to specify if Dialer Errors (error messages that indicate a
problem between the SAFECOM Radio Communicator and the host Alarm Panel) will be reported to the Automation
Software. “NO ” = Dialer Errors will not be reported to the Automation software. “YES” = Dialer Errors will be reported
to the Automation software as the 2-digit hexadecimal alarm event code “ 00 “ for Dialer Error.
Report RF Trouble/Restore? Y or N: Allows the operator to specify if RF Trouble/Restore messages will be
reported to the Automation Software. “NO ” = RF Trouble/Restore will not be reported to the Automation software.
“YES” = RF Trouble/Restore will be reported to the Automation software as the 2-digit hexadecimal alarm event code
“ 00 “ for RF Trouble.
Report Remote com Restore? Y or N: Allows the operator to specify if Remote com Restore messages will be
reported to the Automation Software. “NO ” = Remote com Restore will not be reported to the Automation software.
“YES” = Remote com Restore will be reported to the Automation software as the 2-digit hexadecimal alarm event
code “ 00 “ for Remote com Restore.
Report Remote Restarts? Y or N: Allows the operator to specify if Remote Restart messages will be reported to the
Automation Software. “NO ” = Remote Restart will not be reported to the Automation software. “YES” = Remote
Restart will be reported to the Automation software as the 2-digit hexadecimal alarm event code “ XX “ for Remote
Restart.
Report Channel Busy/Channel Clear? Y or N: Allows the operator to specify if Channel Busy/Channel Clear
messages will be reported to the Automation Software. “NO ” = Channel Busy/Channel Clear will not be reported to
the Automation software. “YES” = Channel Busy/Channel Clear will be reported to the Automation software as the 2-
digit hexadecimal alarm event code “ XX “ for Channel Busy.
Print All Events? Y or N: Allows the operator to specify if low priority events sent to the Automation software are
printed on the SAFECOM printer. If “YES”, then all events will be routed to the SAFECOM printer for hard copy.