Bosch DVA-12T Manual de Instalação

Consulte online ou descarregue Manual de Instalação para Sistemas de segurança - controlo de acesso Bosch DVA-12T. Bosch DVA-12T Installation manual [en] Manual do Utilizador

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 72
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 0
RAID Subsystem DVA-16K
DVA-16K SCSI Premium Series
en Installation Manual
Vista de página 0
1 2 3 4 5 6 ... 71 72

Resumo do Conteúdo

Página 1 - RAID Subsystem DVA-16K

RAID Subsystem DVA-16KDVA-16K SCSI Premium Seriesen Installation Manual

Página 2

10 en | Introduction RAID Subsystem DVA-16K | Installation ManualF.01U.027.799 | V2 | 2008.08 Bosch Security System2.3 Best Practices2.3.1 Avoiding Po

Página 3 - Table of Contents

RAID Subsystem DVA-16K | Installation Manual Introduction | en 11 Bosch Security System F.01U.027.799 | V2 | 2008.08Fig. 2.3 RAID subsystem Overview 2

Página 4

12 en | Introduction RAID Subsystem DVA-16K | Installation ManualF.01U.027.799 | V2 | 2008.08 Bosch Security System2.4.4 Hard Drive NumberingThe front

Página 5

RAID Subsystem DVA-16K | Installation Manual Introduction | en 13 Bosch Security System F.01U.027.799 | V2 | 2008.082.5 Subsystem ComponentsThe RAID s

Página 6 - 1 Warnings and Certifications

14 en | Introduction RAID Subsystem DVA-16K | Installation ManualF.01U.027.799 | V2 | 2008.08 Bosch Security System2.5.3 The RAID Controller ModuleThe

Página 7 - CB (Certified Worldwide)

RAID Subsystem DVA-16K | Installation Manual Introduction | en 15 Bosch Security System F.01U.027.799 | V2 | 2008.082.5.5 DIMM ModuleThe controller mo

Página 8 - 2 Introduction

16 en | Introduction RAID Subsystem DVA-16K | Installation ManualF.01U.027.799 | V2 | 2008.08 Bosch Security SystemFig. 2.11 PSU ModuleFor the PSU spe

Página 9 - 2.2 Management

RAID Subsystem DVA-16K | Installation Manual Introduction | en 17 Bosch Security System F.01U.027.799 | V2 | 2008.082.6 Subsystem MonitoringThe RAID s

Página 10 - 2.4 Enclosure Chassis

18 en | Introduction RAID Subsystem DVA-16K | Installation ManualF.01U.027.799 | V2 | 2008.08 Bosch Security System2.7 Hot-swappable Components2.7.1 H

Página 11 - 2.4.3 Front Panel Overview

RAID Subsystem DVA-16K | Installation Manual Hardware Installation | en 19 Bosch Security System F.01U.027.799 | V2 | 2008.083 Hardware Installation3.

Página 13 - 2.5 Subsystem Components

20 en | Hardware Installation RAID Subsystem DVA-16K | Installation ManualF.01U.027.799 | V2 | 2008.08 Bosch Security System3.3 Safety Precautions3.3.

Página 14

RAID Subsystem DVA-16K | Installation Manual Hardware Installation | en 21 Bosch Security System F.01U.027.799 | V2 | 2008.083.4 General Installation

Página 15 - 2.5.7 Power Supply Units

22 en | Hardware Installation RAID Subsystem DVA-16K | Installation ManualF.01U.027.799 | V2 | 2008.08 Bosch Security System3.6 Rack/Cabinet Installat

Página 16 - 2.5.8 Cooling Modules

RAID Subsystem DVA-16K | Installation Manual Hardware Installation | en 23 Bosch Security System F.01U.027.799 | V2 | 2008.08Fig. 3.3 Installing a Dri

Página 17 - 2.6 Subsystem Monitoring

24 en | Subsystem Monitoring RAID Subsystem DVA-16K | Installation ManualF.01U.027.799 | V2 | 2008.08 Bosch Security System4 Subsystem Monitoring 4.1

Página 18 - 2.7 Hot-swappable Components

RAID Subsystem DVA-16K | Installation Manual Subsystem Monitoring | en 25 Bosch Security System F.01U.027.799 | V2 | 2008.084.2 Status Indicating LED

Página 19 - 3 Hardware Installation

26 en | Subsystem Monitoring RAID Subsystem DVA-16K | Installation ManualF.01U.027.799 | V2 | 2008.08 Bosch Security SystemThree (3) LEDs monitor the

Página 20 - 3.3 Safety Precautions

RAID Subsystem DVA-16K | Installation Manual Subsystem Monitoring | en 27 Bosch Security System F.01U.027.799 | V2 | 2008.084.2.3 Drive Tray LEDsTwo

Página 21 - 3.5 Unpacking the Subsystem

28 en | Subsystem Monitoring RAID Subsystem DVA-16K | Installation ManualF.01U.027.799 | V2 | 2008.08 Bosch Security SystemLED Name Color Status1 Rea

Página 22 - 3.7 Drive Tray Installation

RAID Subsystem DVA-16K | Installation Manual Subsystem Monitoring | en 29 Bosch Security System F.01U.027.799 | V2 | 2008.084.2.5 LAN Port LEDsA shie

Página 23

RAID Subsystem DVA-16K | Installation Manual Table of Contents | en 3 Bosch Security System F.01U.027.799 | V2 | 2008.08Table of Contents1 Warnings an

Página 24 - 4 Subsystem Monitoring

30 en | Subsystem Monitoring RAID Subsystem DVA-16K | Installation ManualF.01U.027.799 | V2 | 2008.08 Bosch Security System4.2.8 Cooling Module LEDsE

Página 25 - 4.2 Status Indicating LEDs

RAID Subsystem DVA-16K | Installation Manual Subsystem Monitoring | en 31 Bosch Security System F.01U.027.799 | V2 | 2008.084.3 Audible AlarmDifferen

Página 26 - Fig. 4.1 LCD Panel

32 en | Subsystem Monitoring RAID Subsystem DVA-16K | Installation ManualF.01U.027.799 | V2 | 2008.08 Bosch Security System4.4 MonitoringPresence det

Página 27 - 4.2.4 Controller Module LEDs

RAID Subsystem DVA-16K | Installation Manual Subsystem Connection and Operation | en 33 Bosch Security System F.01U.027.799 | V2 | 2008.085 Subsystem

Página 28

34 en | Subsystem Connection and Operation RAID Subsystem DVA-16K | Installation ManualF.01U.027.799 | V2 | 2008.08 Bosch Security System5.1.3 SCSI Te

Página 29 - 4.2.7 PSU LEDs

RAID Subsystem DVA-16K | Installation Manual Subsystem Connection and Operation | en 35 Bosch Security System F.01U.027.799 | V2 | 2008.085.2 Host Con

Página 30 - 4.2.8 Cooling Module LEDs

36 en | Subsystem Connection and Operation RAID Subsystem DVA-16K | Installation ManualF.01U.027.799 | V2 | 2008.08 Bosch Security SystemWhen setting

Página 31 - 4.3 Audible Alarm

RAID Subsystem DVA-16K | Installation Manual Subsystem Connection and Operation | en 37 Bosch Security System F.01U.027.799 | V2 | 2008.08When setting

Página 32 - 4.4 Monitoring

38 en | Subsystem Connection and Operation RAID Subsystem DVA-16K | Installation ManualF.01U.027.799 | V2 | 2008.08 Bosch Security System5.3 Daisy Cha

Página 33 - 5.1 SCSI Connection Overview

RAID Subsystem DVA-16K | Installation Manual Subsystem Connection and Operation | en 39 Bosch Security System F.01U.027.799 | V2 | 2008.085.4 Power On

Página 34 - 5.1.3 SCSI Termination

4 en | Table of Contents RAID Subsystem DVA-16K | Installation ManualF.01U.027.799 | V2 | 2008.08 Bosch Security System4 Subsystem Monitoring . . . .

Página 35 - 5.2 Host Connection Topology

40 en | Subsystem Connection and Operation RAID Subsystem DVA-16K | Installation ManualF.01U.027.799 | V2 | 2008.08 Bosch Security System3. Power on t

Página 36 - 5.2.2 Dual Hosts

RAID Subsystem DVA-16K | Installation Manual Subsystem Connection and Operation | en 41 Bosch Security System F.01U.027.799 | V2 | 2008.08The LCD scre

Página 37

42 en | Subsystem Maintenance RAID Subsystem DVA-16K | Installation ManualF.01U.027.799 | V2 | 2008.08 Bosch Security System6 Subsystem Maintenance6.1

Página 38 - 5.3 Daisy Chain

RAID Subsystem DVA-16K | Installation Manual Subsystem Maintenance | en 43 Bosch Security System F.01U.027.799 | V2 | 2008.086.2 Replacing Controller

Página 39 - 5.4 Power On

44 en | Subsystem Maintenance RAID Subsystem DVA-16K | Installation ManualF.01U.027.799 | V2 | 2008.08 Bosch Security SystemFig. 6.2 Removing the Cont

Página 40 - 5.4.4 LCD Screen

RAID Subsystem DVA-16K | Installation Manual Subsystem Maintenance | en 45 Bosch Security System F.01U.027.799 | V2 | 2008.08Fig. 6.5 Installing the C

Página 41 - 5.5 Power Off Procedure

46 en | Subsystem Maintenance RAID Subsystem DVA-16K | Installation ManualF.01U.027.799 | V2 | 2008.08 Bosch Security System6.3 DIMM Module Replacemen

Página 42 - 6 Subsystem Maintenance

RAID Subsystem DVA-16K | Installation Manual Subsystem Maintenance | en 47 Bosch Security System F.01U.027.799 | V2 | 2008.083. Re-insert the new DIMM

Página 43 - • Controller module

48 en | Subsystem Maintenance RAID Subsystem DVA-16K | Installation ManualF.01U.027.799 | V2 | 2008.08 Bosch Security System6.4 Replacing a Faulty BBU

Página 44

RAID Subsystem DVA-16K | Installation Manual Subsystem Maintenance | en 49 Bosch Security System F.01U.027.799 | V2 | 2008.08Fig. 6.9 Installing the B

Página 45

RAID Subsystem DVA-16K | Installation Manual Table of Contents | en 5 Bosch Security System F.01U.027.799 | V2 | 2008.087 Appendix: Specifications. .

Página 46 - 6.3 DIMM Module Replacement

50 en | Subsystem Maintenance RAID Subsystem DVA-16K | Installation ManualF.01U.027.799 | V2 | 2008.08 Bosch Security System6.5 Replacing a Faulty PSU

Página 47

RAID Subsystem DVA-16K | Installation Manual Subsystem Maintenance | en 51 Bosch Security System F.01U.027.799 | V2 | 2008.08Fig. 6.11 Power Sockets a

Página 48 - 6.4.2 Procedure

52 en | Subsystem Maintenance RAID Subsystem DVA-16K | Installation ManualF.01U.027.799 | V2 | 2008.08 Bosch Security System7. Insert the previously r

Página 49

RAID Subsystem DVA-16K | Installation Manual Subsystem Maintenance | en 53 Bosch Security System F.01U.027.799 | V2 | 2008.086.6 Cooling Module Mainte

Página 50 - 6.5.1 PSU Module Overview

54 en | Subsystem Maintenance RAID Subsystem DVA-16K | Installation ManualF.01U.027.799 | V2 | 2008.08 Bosch Security SystemFig. 6.18 Installing the n

Página 51 - PSU Handle

RAID Subsystem DVA-16K | Installation Manual Subsystem Maintenance | en 55 Bosch Security System F.01U.027.799 | V2 | 2008.086.7 Replacing a Failed Ha

Página 52

56 en | Subsystem Maintenance RAID Subsystem DVA-16K | Installation ManualF.01U.027.799 | V2 | 2008.08 Bosch Security System6.7.2 Replacing a Hard Dri

Página 53 - Silver Handle

RAID Subsystem DVA-16K | Installation Manual Subsystem Maintenance | en 57 Bosch Security System F.01U.027.799 | V2 | 2008.08Fig. 6.22 Removing the SA

Página 54

58 en | Appendix: Specifications RAID Subsystem DVA-16K | Installation ManualF.01U.027.799 | V2 | 2008.08 Bosch Security System7 Appendix: Specificati

Página 55

RAID Subsystem DVA-16K | Installation Manual Appendix: Specifications | en 59 Bosch Security System F.01U.027.799 | V2 | 2008.08Safety Requirements• U

Página 56 - 6.7.2 Replacing a Hard Drive

6 en | Warnings and Certifications RAID Subsystem DVA-16K | Installation ManualF.01U.027.799 | V2 | 2008.08 Bosch Security System1 Warnings and Certif

Página 57

60 en | Appendix: Specifications RAID Subsystem DVA-16K | Installation ManualF.01U.027.799 | V2 | 2008.08 Bosch Security System7.2 Controller Specific

Página 58 - 7 Appendix: Specifications

RAID Subsystem DVA-16K | Installation Manual Appendix: Specifications | en 61 Bosch Security System F.01U.027.799 | V2 | 2008.087.3 Drive Tray Specifi

Página 59 - • System LEDs

62 en | Appendix: Specifications RAID Subsystem DVA-16K | Installation ManualF.01U.027.799 | V2 | 2008.08 Bosch Security System7.5 Cooling Module Spec

Página 60 - 7.2 Controller Specifications

RAID Subsystem DVA-16K | Installation Manual Appendix: Specifications | en 63 Bosch Security System F.01U.027.799 | V2 | 2008.087.7 Fault Tolerance Ma

Página 61 - 7.3 Drive Tray Specifications

64 en | Appendix: Spare Parts and Accessories RAID Subsystem DVA-16K | Installation ManualF.01U.027.799 | V2 | 2008.08 Bosch Security System8 Appendix

Página 62 - 7.6 RAID Management

RAID Subsystem DVA-16K | Installation Manual Appendix: Pin Outs | en 65 Bosch Security System F.01U.027.799 | V2 | 2008.089 Appendix: Pin Outs9.1 VHDC

Página 63

66 en | Appendix: Pin Outs RAID Subsystem DVA-16K | Installation ManualF.01U.027.799 | V2 | 2008.08 Bosch Security System9.2 DB9 Audio Jack Pin OutsTh

Página 64 - 8.2 Accessories

RAID Subsystem DVA-16K | Installation Manual Appendix: Pin Outs | en 67 Bosch Security System F.01U.027.799 | V2 | 2008.089.3 DB9 Audio Jack UPS Cable

Página 65 - 9 Appendix: Pin Outs

68 en | Appendix: Pin Outs RAID Subsystem DVA-16K | Installation ManualF.01U.027.799 | V2 | 2008.08 Bosch Security System9.5 Ethernet Port Pin OutsFig

Página 66 - 9.2 DB9 Audio Jack Pin Outs

RAID Subsystem DVA-16K | Installation Manual Index | en 69 Bosch Security System F.01U.027.799 | V2 | 2008.0810 IndexAairflow 20airflow clearance 20am

Página 67 - 9.4 Null Modem

RAID Subsystem DVA-16K | Installation Manual Warnings and Certifications | en 7 Bosch Security System F.01U.027.799 | V2 | 2008.081.3 CertificationsFC

Página 68 - 9.6 Main Power

70 en | Index RAID Subsystem DVA-16K | Installation ManualF.01U.027.799 | V2 | 2008.08 Bosch Security SystemRrack cabinet 20rackmounting 22rear panel

Página 70

Bosch Security System Robert-Koch-Straße 100D-85521 OttobrunnGermanyTelefon +49 (89) 6290-0Fax +49 (89) 6290-1020www.bosch-securitysystems.com © Bosch

Página 71

8 en | Introduction RAID Subsystem DVA-16K | Installation ManualF.01U.027.799 | V2 | 2008.08 Bosch Security System2 IntroductionThis manual covers the

Página 72

RAID Subsystem DVA-16K | Installation Manual Introduction | en 9 Bosch Security System F.01U.027.799 | V2 | 2008.08Two (2) dual-stacked VHDCI SCSI con

Comentários a estes Manuais

Sem comentários