2.2.1 Keypad/DACM Partition Assignment
• Addresses: 3139 to 3146
• Data Digit: See Table 17
• Default: 0
• Selections: See Table 18
Use Table 17 and Table 18 to assign a keypad or DACM to an area (partition). Select an area assignment value
from Table 18, and enter that value in the appropriate data digit for each address in Table 17. For example, if you
want Keypad/DACM 1 to be assigned to Area 3, enter a “2” in Data Digit 1 for Address 3139.
Table 17: Address 3139 to 3146 Keypad/DACM Partition Assignment
Address Data
Digit
Keypad/
DACM
Default Assigned
Value
Address Data
Digit
Keypad/
DACM
Default Assigned
Value
3139 1 1* 0
❒
3143 1 9 0
❒
2 2* 0
❒
2 10 0
❒
3140 1 3 0
❒
3144 1 11 0
❒
2 4 0
❒
2 12 0
❒
3141 1 5 0
❒
3145 1 13 0
❒
2 6 0
❒
2 14 0
❒
3142 1 7 0
❒
3146 1 15 0
❒
2 8 0
❒
2 This Data Digit
must be 0.
0
* Keypad only
Table 18: Address 3139 to 3146 Keypad Partition Assignment Selections
Select Option Value
Belongs to Area 1
0
Belongs to Area 2 1
Belongs to Area 3 2
Belongs to Area 4 3
Belongs to Area 5 4
Belongs to Area 6 5
Belongs to Area 7 6
Belongs to Area 8 7
The DACM Partition Assignment’s assigned value (Table 17 and Table 18) and the Zone Partition
Assignment’s assigned value must be the same.
For example, if you assign a DACM to Partition 2 and the DACM is tied to Zone 9, then you must
assign Zone 9 to Partition 2. For information on assigning the Zone Partition Assignment’s value, refer
to “Zone Partition Assignment” in the DS7400XiV4-EXP Control Panel Reference Guide
(P/N: 4998154963).
Refer to the DACM Operation Instructions (P/N: F01U500997) for instructions on using the DACM with the
control panel.