AMC2 4W Installing | en 41
Bosch Security Systems Installation manual F.01U.024.965 | V.4 | 2006.09
5.11 Connecting Relay Outputs
To operate locks or alarm systems the AMC2 4W has eight form
C relay outputs. The outputs will be connected to the 3-pin
pluggable screw connectors: S5, S6, S10, S11, S17, S18, S22,
and S23 - see Figure 7.5.
Fig. 5.18 Location of the relay output connectors
Each relay output can operate in ‘wet’ mode, using the
AMC2 4W's internal 12V DC power supply for external devices
or ‘dry’ mode with potential free contacts for externally pow-
ered systems.