D9412GV3/D7412GV3 | Operation and Installation Guide | Appendix A: System Wiring Diagrams, Issue A
68 Bosch Security Systems, Inc. | 2/10 | F01U143070-01
Figure 35: D9412GV3, Input Points and Peripheral Devices
P105BL
D125B
Sw . Au x Pw r
Zone B
Zone A
Pn l C om mo n
Pn l C om mo n
Loop B-
Loop A-
Loop B+
Loop A+
Earth Ground
10
9
5
4
3
8
2
1
7
6
D129
Aux P ow er
Zone B
Zone A
Comm on
Loop B-
Loop A-
Loop B+
Loop A+
Earth Ground
10
9
5
4
3
8
2
1
7
6
11
12
13
Loop A+
Loop A-
Loop B+
Loop B-
P105F
COM MO N
VO LTAG E RANG ES
O p en 3 . 7 - 5 . 0 VD C
Nor mal 2.0 - 3.0 VDC
Short 0.0 - 1.3 VDC
+-
D130
TE LC O
RI NGTIP
PH O NE LI NE
SE IZED
27
25
EART H GROUND
COM MO N
REL AY A
REL AY B
REL AY C
S4 GROUND FAULT DET ECT
En ab led
Di sa bl ed
RE D
ON w h en co mm u ni cati ng
OFF when idle
ZONEX IN 1
26
ZONEX POWER +
24
ZONEX COM MON
23
PHONE LINE SEIZED LED
TI P R ING
TELCO CORD MODEL D 161
ZONEX OUT 2
ZONEX IN 2
PR OGR AMM ABLE
ALA RM O UTPUT S
Terminals
SWITC HED AUX
and6
7
Ter minal 8
Operation Mo n itor LED
Pulses when Norma l
Flickers when Ringing
GRE EN
D5200/D5360
PROG CONN
Point 8, S3 O ption
Clo sed = 1 k
Ω
EOL
Norma l Op e r at i on
Open =AB-12 UL
Bell Box 220 k
Ω
25
Point 3 Point 4
161514
Point 1Point 2
1211 13
Point 5 Point 6
1817 19
Point 7Point 8
2120 22
27
BATTERY N EGATIVE O NLY
BATTERY PO SITIVE ONLY
+ A UX PO WER
CLASS 2 TRANSFORMER
16.5 VAC 40 VA 60 Hz
Mo del D1640
Internally Fused - Do not short
Requ ires U n s wi t ch ed Ou t let
Do not share with other equipment
RED POWER +
YELLOW DATA BUS A
GRE E N DA TA BUS B
BLACK COMM ON
ZONEX OUT 1N.F.P.A.
Style 4.0
Signaling
Line
Circuits
CAU TION: Avoid damage to Pane l.
Do not connect 24 V to terminals.
Maximum charging current 1.4 A
D9412GV3
1 - (Optional): For 24 V applications use a UL Listed
24 VDC power supply with a D130 Relay Module.
Refer to the D130 Installation Instructions
(P/N: F01U072455) for correct wiring
requirements.
2 - D130 Relay Module
3 - D125B Powered Loop Interface Module
4 - To UL Listed two-wire smoke detectors. Refer to
Two-Wire Smoke Detectors in the
D9412GV3/D7412GV3 Approved Applications
Compliance Guide (P/N: F01U143069) for a
listing of compatible two-wire smoke detectors.
5 - P105F 1 k EOL resistor (P/N: 14-03130-004):
Suitable for non-powered initiating and
supervisory devices such as pull stations, heat
sensors, and valve tampers.
6 - P105BL1 1k EOL resistor (P/N: 16179B): For
typical burglar alarm applications.
7 - D129 Dual Class A Initiation Circuit Module:
Provides optional Waterflow Alarm Retard
feature. Not suitable for two-wire smoke
detectors.
Use zero retard except for waterflow devices.
All external connections except Terminal 5 (battery positive) are power limited.