18 en | Turning the System ON or OFF and Keypad Commands D9412GV4/D7412GV4/D7212GV4
F01U215242 | 01 | 2011.10 Quick Reference Guide Bosch Security Systems, Inc.
6 - Tools menu (Requires Service Passcode)
Programming
Service Bypass
–RF Points
RF Repeaters
–RF Diagnostics
–IP Diagnostics
7 - Firmware Updates
8.3 SIA CP-01 False Alarm Prevention Options
Master Arm-No Exit=YES: This setting provides for a Perimeter Delay point to be faulted
when master arming each area, or the arming state defaults to Perimeter Delayed.
Exit Delay Warning=YES: When this parameter is set to YES, the alarm bell pulses on and
off every two seconds for the remaining 10 sec of Exit Delay.
Entry Delay Warning=YES: When this parameter is set to YES, the alarm bell pulses on
and off every two seconds for the remaining 10 sec of Entry Delay.
NOTICE!
Some programming parameters are preset for compliance with SIA standard CP-01 (false
alarm prevention). These settings are in AREA WIDE PARAMETERSArea Parameters. They
affect control panel operation as described below.