Access Control Interface Module Installation | en 13
Bosch Security Systems, Inc. Installation and Operation Guide F.01U.215.244 | 05 | 2012.06
3 Installation
Thank you for choosing our product. We have made an effort to identify the key steps for
installing the interface module. To ensure installation goes smoothly, follow the installation
steps in the order presented.
3.1 System Planning
Before proceeding, Bosch recommends drawing the system layout on a sheet of graph paper.
Also, review the architect and engineering drawings, if available. This will help in setting
addresses, marking the units, and routing and tag wires. The drawing should include the
control panel, the interface module, the trip switches for RTE/REX, doors, readers, control
centers assigned to the same area as the interface modules, and the wiring run.
Have the following documents handy while reading through this manual:
Access Control Interface Module Program Entry Guide.
Access Control Interface Module Program Record Sheet.
Control/Communicator Program Entry Guide and Program Record Sheet.
Security System Owner’s Manual.
Power Supply Installation Instructions.
Also, become familiar with the operation of the Remote Programming System (RPS) or the
D5200 programmer.
3.2 Procedure
3.2.1 Mounting the enclosure and installing the interface module
Enclosure Placement
The maximum distance allowance between the interface module and Wiegand card
readers is 500 feet (152 m).
Using 22 AWG (0.8 mm) wire, the interface module may be remoted up to 2500 feet (762
m) away from the control panel; using 18 AWG (1.2 mm) wire, the interface module may
be remoted up to 5000 feet (1524 m).
Consider placing the enclosure where a technician can gain easy access for
troubleshooting the unit and where wiring can be routed easily.
3.2.2 Pulling and Marking the Wires
Running wire.
Use Table 3.1 Typical Wire Planning Chart for the D9210C to estimate the wire bundle size
for your knockouts and where to mount the interface module.
Tag your wire runs to prevent confusion during installation and troubleshooting. Section
Figure 3.1 Wiring Diagram for Typical D9210C installation shows the wiring for a typical
interface module installation.