50 en | Default Configuration DiBos/DiBos Micro
F.01U.033.308 | V7 | 2009.09 Installation Guide Bosch Sicherheitssysteme GmbH
6.2.4 Configuring Tamper Detection
Video and audio connections menu > Camera section > Edit button
Make the settings for each camera as required.
1 Tamper detection Click the tab. The entire image content inside the blue frame
is initially not selected.
2Show camera
warnings
Activate the check box if a warning is to be shown for camera
problems (image too light, too dark, noisy). The values that
trigger the warning are stored in the software and cannot be
changed.
Note:
With pan/tilt cameras, panning the camera can cause the
message "Video signal noisy" to be displayed when there is
no malfunction.
3 Activate Select the check box to activate the Reference image check.
4 Time periods Click the arrow to display the time periods available. Select
the time periods for which the reference image check is
activated.
5 Within the blue frame
(image window)
Displays the current live image and the area being monitored.
The image is updated every second.
Left-click or hold the
left mouse button
down and drag an area
A plus sign appears beside the mouse cursor to show that the
area has been selected and is being monitored for tampering.
Areas being monitored for tampering are shown shaded in
yellow.
Right-click or hold the
right mouse button
down and drag an area
A minus sign appears beside the mouse cursor to show that
the area has not been selected. Unshaded areas are not being
monitored.