142 en | Connections DiBos/DiBos Micro
F.01U.033.308 | V7 | 2009.09 Installation Guide Bosch Sicherheitssysteme GmbH
9.10.3 Connecting to SAE Dome Cameras (Directly)
9.10.4 Connecting to SAE Dome Cameras with V3032 Biphase Interface
1 Video system 4 RS 232/RS 485 converter e.g. LNL-108
A
2 COM x 5 RS 485
3RS 232 6SAE Dome
1
5
2
6
3
4
1 Video system 5 RS 485
2Biphase 6SAE dome camera
3 Code multiplexer LTC 8569 or LTC
8570
7 LTC matrix switch
4 Protocol converter SAE (V3032)
1
522
2
63
7
4
NOTICE!
An LTC 8569 or LTC 8570 is needed if a Bosch LTC matrix switch is connected to the video
system at the same time as an SAE Dome.