Bosch 7000 Series Manual do Utilizador

Consulte online ou descarregue Manual do Utilizador para Câmaras de segurança Bosch 7000 Series. Bosch VG5-7220-CPT4 Manual do Utilizador

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir

Resumo do Conteúdo

Página 1 - AUTODOME IP 7000 HD

AUTODOME IP 7000 HDVG5-7130, VG5-7230 en Operation Manual

Página 2

SELV - All the input/output ports are Safety Extra Low Voltage (SELV) circuits. SELV circuitsshould only be connected to other SELV circuits.Because t

Página 3 - Table of contents

lower the frame refresh rate depending on the settings for the maximum data rate undernetwork settings. A higher quantization value results in low ima

Página 4

Options with “H.264 MP 720p50/60 Fixed” selected forStream 1:– Copy Stream 1– H.264 MP SD– H.264 MP 720p6/7 Fixed– H.264 MP upright (cropped)– H.264 M

Página 5

HD Profiles (Configuration Parameters)DSL OptimizedTarget bit rate: 380 kbpsMaximum bit rate: 500 kbpsEncoding interval: 30.00 ips3G OptimizedTarget b

Página 6 - Safety EN

Notice!Draw the mask 10% larger than the object to ensure that the mask completely covers theobject as the camera zooms in and out. Click the Zoom thr

Página 7 - Safety EN

Color hueThe degree of color in the video image (HD only). Values range from -14° to 14°; the default is8°.Gain controlAdjusts the automatic gain cont

Página 8 - Important Notices

Backlight compensationOptimizes the video level for the selected area of the image. Parts outside this area may beunderexposed or overexposed. Select

Página 9

Lens SettingsAutofocusContinuously adjusts the lens automatically to the correct focus for the sharpest picture.– One Push (default; commonly called “

Página 10

– Scene 1: camera returns to Preset 1.– Previous Aux: camera returns to the previous activity.Inactivity periodDetermines the behavior of the dome whe

Página 11

3. Click the View Control link, under the image cameo, to access the directional and zoomcontrols.4. Use the View Control dialog box to make the neces

Página 12 - Customer Support and Service

Type 8 in the input box and click the Aux On button.5. To stop the tour, type 8 and click the Aux Off button.Notice!Refer to the document “AUTODOME_Op

Página 13 - Unpacking

instructions, générer des interférences nuisibles aux communications radio. L’utilisation de ceproduit dans une zone résidentielle peut provoquer des

Página 14

Line OutYou can set the line output gain with the slider (from 0 (zero) to 79, with 0 as the default).Make sure that the display does not go beyond th

Página 15 - Tools Required

1. Enter the IP address of the required iSCSI destination in the iSCSI IP address field.2. If the iSCSI destination is password protected, enter this

Página 16

Deactivating Storage MediaYou can deactivate any storage medium from the Managed storage media list. It is then nolonger used for recordings.1. Click

Página 17 - Additional Products Required

Alarm input / Analysis alarm / Video loss alarmHere you can select the alarm sensor that is to trigger a recording.Virtual alarmHere you can select th

Página 18 - System overview

HolidaysYou can define holidays that are not in the standard weekly schedule on which recordings areto apply. This allows you to apply a schedule for

Página 19 - Pre-installation Checklist

Advanced Mode: AlarmAlarm ConnectionsYou can select how the camera responds to an alarm. In the event of an alarm, the unit canautomatically connect t

Página 20 - Stabilization

Notice!If you enter the destination IP address 0.0.0.0 for destination 10, this address will no longerbe used for the tenth attempt at automatic conne

Página 21

Auto-connectSelect the On option to automatically re-establish a connection to one of the previouslyspecified IP addresses after each reboot, after a

Página 22 - Corner Mounts)

You can rename the profile.1. To rename the file, click the icon to the right of the list field and enter the new profilename in the field.2. Click th

Página 23 - Warning!

The sensor reacts to variations in the brightness of the video image. The darker theobservation area, the higher the value that must be selected.Minim

Página 24 - (Pole) Mounts

Connection in Applications24 VAC power source: This unit is intended to operate with a limited power source. The unitis intended to operate at 24 VAC

Página 25

Global changeYou can set how large the global change in the video image must be for an alarm to betriggered. This setting is independent of the sensor

Página 26 - 5 4 3 2 1

Notice!Select only those areas for reference monitoring in which no movement takes place and thatare always evenly lit, as false alarms could otherwis

Página 27

!Caution!Do not use any special characters, for example &, in the name.Special characters are not supported by the system's internal recordin

Página 28 - Figure 7.3: VG4-PSU1/VG4-PSU2

Sender addressEnter a unique name for the e-mail sender, for example the location of the device. This willmake it easier to identify the origin of the

Página 29

Aux On: defines a standard or custom keyboard ON command. Refer to User CommandTable, page 151 for a list of valid commands.Note: Only commands 1, 8,

Página 30 - 24V NC 24V

Some changes only take effect after the unit is rebooted. In this case, the Set button changesto Set and Reboot.1. Make the desired changes.2. Click t

Página 31

!Caution!Multicast operation is only possible with the UDP protocol. The TCP protocol does notsupport multicast connections.The MTU value in UDP mode

Página 32

DynDNSEnable DynDNSDynDNS.org is a DNS hosting service that stores IP addresses in a database ready for use. Itallows you to select the camera via the

Página 33

To configure the unit, you must connect the camera directly to a computer using a networkcable. This is because communication via the network is not e

Página 34

Quality of serviceThe camera offers Quality of Service (QoS) configuration options to ensure fast networkresponse to PTZ data and images. Quality of S

Página 35

UnpackingThis equipment should be unpacked and handled with care. If an item appears to have beendamaged in shipment, notify the shipper immediately.V

Página 36

PortAssign a different port to each data stream if there are simultaneous data streams at the samemulticast address.Enter the port address of the requ

Página 37

Maximum image widthEnter a number for the maximum width, in pixels, for the saved images.AccountsIn order to configure image posting, and to save and

Página 38

The preferred method to update your camera is through a direct connection between thecamera and a PC. This method entails connecting the Ethernet cabl

Página 39 - Caution!

1. Enter the full path of the file to upload or click Browse to select the required file.2. Next, click Upload to begin transferring the file to the u

Página 40 - Description

OperationUsing the AUTODOME CameraThe AUTODOME 7000 transmits PTZ control commands and images over a TCP/IP network. Italso allows users to configure

Página 41

Maximum Number of ConnectionsIf you do not connect, the unit may have reached its maximum number of connections.Depending on the unit and network conf

Página 42 - P106 P105

2 Tilts the camera down 9 Focus near²3 Pans the camera to the left 10 Iris close²4 Pans the camera to the right 11 Iris open²5 Pans and tilts the came

Página 43

Triggering RelayYou can switch connected units using the relays in the camera (for example, lights or dooropeners).4 To activate this, click the icon

Página 44 - RJ45 Ethernet socket

1 Command number field2 Keypad (numbers 0-9)3 Show a preset scene4 Set a preset scene5 Initiates a command6 Deletes a number in the Command Number fie

Página 45 - 6 5 4 3 2 1

2. Click the Show scene button.Notice!For more information about the camera settings and controls, click the Help on this page?link to open the online

Página 46 - LINE NC NEUT

Mounting Options Part Numbers– Power Box with 120 VAC transformeror with 230 VAC transformerVG4-A-PA1VG4-A-PA2Power Supply Box and cover with 120 VAC

Página 47 - Installing the VGA-ROOF-MOUNT

Recording Video SequencesYou can save sections of the video sequence currently shown on the LIVE page on yourcomputer's hard drive. The icon for

Página 48

Selecting RecordingsAll saved sequences are displayed in a list. A track number is assigned to each sequence. Starttime and stop time, recording durat

Página 49 - Figure 8.8: VGA-ROOF-MOUNT

Using Intelligent TrackingConfiguring Intelligent TrackingThe camera utilizes the built-in Intelligent Video Analytics (IVA) to continuously follow an

Página 50 - Figure 8.9: Attach Dome Cap

– Mount the camera in the most stable position. Avoid locations affected by vibrations,such as those caused by a roof-top air conditioner. These vibra

Página 51 - 5 in

If the Intelligent Tracking feature is set to Auto or Click, the live video image displays an eyeicon with a symbol that conveys the state of Intellig

Página 52 - Wire the Pipe Interface Board

Recommended Use of Your CameraBosch recommends that you consider the following in order to optimize the life of your Boschcamera.Notice!Refer to the d

Página 53

TroubleshootingIf you experience difficulties operating your AUTODOME camera, refer to the following. If theguidelines do not enable you to solve the

Página 54

Problem Questions to Ask/Actions to Resolve the ProblemPicture is dark – Check that the Gain Control is set to High via the Settings menu.If O.K., the

Página 55

MaintenanceThe bubble is made of Acrylic or Polycarbonate, depending on the application. Polycarbonatebubbles provide high impact resistance, and its

Página 56

Cleaning the Bubble ExteriorThe exterior of the bubble is hard coated for extra protection. If cleaning becomes necessary,only use cleaning solutions

Página 57

Tools RequiredQuantity Item For Mount Type Supplied byBosch?1 Allen wrench, 5 mm Pendant Arm to:– Wall Mount– Corner Mount– Mast (pole) Mount– Roof pa

Página 58

Technical dataFor product specifications, see the datasheets for AUTODOME IP 7000 Series and forAUTODOME HD 7000 Series, available on the appropriate

Página 59

User Command TableNotice!Some of the following commands may not apply to your camera. Locked Alarm RuleOutputFunctionKeyCommNo.Command Description Y

Página 60

Locked Alarm RuleOutputFunctionKeyCommNo.Command DescriptionY On/Off 94 Set Azimuth Zero Point Sets the zero degree pan position. On/Off 95 Displ

Página 62 - Interface Box Connections

Bosch Security Systems, Inc.850 Greenfield RoadLancaster, PA, 17601USAwww.boschsecurity.com© Bosch Security Systems, Inc., 2014Bosch Sicherheitssyst

Página 63

1 Right angle NPS conduitconnector, 3/4 in. (20-mm)Mast (pole) mount with VGA-PEND-WPLATENo1 Screwdriver, mediumstraight blade– Roof parapet Mount– Pi

Página 64

Additional Products RequiredThe following table lists additional products, sold separately by Bosch or other manufacturers,necessary to install AUTODO

Página 65

System overviewThe AUTODOME 7000 Series camera includes the following functionality:Function DescriptionVideo Encoding The camera uses the H.264 compr

Página 66

Pre-installation Checklist1. Determine the location and distance for the power supply box based on its voltage andcurrent consumption.You may choose t

Página 68

StabilizationSurveillance cameras are susceptible to vibrations caused by wind or vibrations emanatingfrom the medium to which the camera is attached.

Página 69 - Preparing the Bubble

Installing the Optional SD CardThe camera can accept a customer-supplied SDHC or SDXC memory card (hereafter referredto as “SD card”) for local storag

Página 70

Mount Power Supply Box (Wall, Mast (Pole), andCorner Mounts)Before mounting the Power Supply Box, decide if you should wire the box through the holes

Página 71

!Warning!For units intended to be installed outdoors: All wiring (power and I/O cabling) connecting tothe unit must be routed separately inside differ

Página 72 - Connection

Installing the Pendant Arm Wall, Corner, and Mast(Pole) MountsDescriptionThis chapter details how to install an AUTODOME to a Wall, Corner, or Mast (p

Página 73 - Ethernet Connections

Connecting Alarm Inputs and Outputs4 To connect alarm inputs and outputs, attach the supplied 6-pin Alarms In and the 4-pinAlarms Out connector plugs

Página 74

Power Supply Box ConnectionsThe following figure is a detailed illustration of the Pendant Arm Power Supply Box, whichincludes the fuse specifications

Página 75 - Alarms and Relay Connections

Cables/wires that are routed through number 2 in the illustration above come from the Nexuscable bundle that is in the pendant Arm.Fuse Specifications

Página 76

!Warning!For units intended to be installed outdoors: All wiring (power and I/O cabling) connecting tothe unit must be routed separately inside differ

Página 77

To properly wire the incoming high voltage and the outgoing low voltage lines, refer to thistable:No. Connector Pin 1 Pin 2 Pin 3 Pin 4 Pin 5 Pin 6

Página 78 - Audio Connections (Optional)

Table of contents1Safety EN 61.1 About this Manual 61.2 Legal Information 61.3 Safety Precautions 61.4 Important Safety Instructions 61.5 Important No

Página 79

!Warning!Ensure that you connect the outgoing power supply wires to the P107 heater connectors (HNand HL). The heater power (XF103) fuse can handle a

Página 80

Attach Pendant Arm to Power Supply BoxThe bottom hinge pin of the Pendant Arm is provided with a Hinge Pin Stop to hold the hingeopen while attaching

Página 81 - Configuration

Make Connections in the Power Supply Box1 2 3Figure 7.8: Pendant Arm connections to Power Supply Box1. Attach the earth ground wire (item 1 in the ill

Página 82 - Configuring the Camera

Installing the VGA-PEND-WPLATEThis section provides instructions to install a wall, corner, or mast mount with the VGA-PEND-WPLATE Mounting Plate inst

Página 83 - Configuration

3. Ensure that the mounting plate is secure.Attach the Pendant Arm to the Mounting PlateThe bottom hinge pin of the Pendant Arm is provided with a Hin

Página 84

4. Once you have the hinges aligned, release the top hinge pin to engage its mating hinge onthe Mounting Plate. Then release the bottom hinge pin from

Página 85 - Configuring Audio (Optional)

Figure 7.11: Mounting Plate - Inside DetailRef.Description1 Grounding lug with two spade terminals2 Earth ground lug with crimp ring terminal3 Wire in

Página 86

14. Attach the 6-pin serial communication mating connector to the Serial Communicationscable (cable 8).15. Connect the Earth ground wire, if available

Página 87

abFigure 7.12: Attach Pendant to Arm1Tilt up.2 Hook and drop.2a Recessed Hinge Pin2b Dome Connector3 Rotate down to engage dome connector.4 Tighten th

Página 88 - Basic Mode: System Overview

!Caution!You must tighten the two mounting screws to a minimum torque of 10-12 N-m (90‑105 in.-lbs)to ensure a proper seal between the arm and the hou

Página 89

11.2 Power Cable and Wire Distances Guides 7211.3 Ethernet Connections 7311.4 Fiber Optic Ethernet Media Converter (Optional) 7411.5 Alarms and Relay

Página 90 - Date/Time

Installing the Roof Parapet and Pipe MountsDescriptionThis chapter details how to install an AUTODOME camera to a Roof Parapet or to a Pipemount. Any

Página 91 - Display Stamping

GND TXD RXD  C+ C-GND TXD RXD  C+ C-P101P106 P105P107XF102 XF103XF1015 4 3 2 1J103J103J103J102J101(LED)HTR

Página 92

GND TXD RXD  C+ C-GND TXD RXD  C+ C-P101P106 P105P107XF102 XF103XF1015 4 3 2 1J103J103J103J102J101(LED)HTR

Página 93 - Appearance

1. Cut and trim the high voltage 115/230 VAC power and ground wires with sufficient slackto reach their connector terminal in the box, but not so long

Página 94 - LIVE Functions

GND TXD RXD  C+ C-P101P106XF102 XF103XF1015 4 3 2 1J103J103J103J102J101(LED)HTR DOME24V NC 24V(FUSE)(FUSE)(FUS

Página 95

Power Supply Box ConnectionsThe following figure is a detailed illustration of the Roof or Pipe Mount Power Supply Box,which includes the fuse specifi

Página 96

No. Connector Pin 1 Pin 2 Pin 3 Pin 4 Pin 5 Pin 6 Ground Grounding ScrewP101 115/230 VAC or24 VAC Power InLine NC Neutral P107 24 VAC Power toDo

Página 97 - Encoder Profile

4. When the hinges are aligned, release the top hinge pin to engage its mating hinge on thepower box. Then release the bottom hinge pin from the Hinge

Página 98

Figure 8.7: Parapet Wall Mount Bracket and Roof Mount Plate1Pipearm 4 Apply sealant around each fastener hole2 Parapet Wall Bracket 5 Roof Mount Plate

Página 99

Figure 8.8: VGA-ROOF-MOUNT1End Cap with O-ring2 Parapet Pipe Arm3 1/4-20 SS Cap Screw4 Down Pipe5 10-24 SS Pan Head Screw7. Fold the video, control,

Página 100 - Encoder Streams

14.32 VCA 11714.33 Virtual Masks 12114.34 Audio Alarm 12114.35 Alarm E-Mail 12214.36 Alarm Task Editor 12314.37 Alarm Rules 12314.38 Advanced Mode: In

Página 101

Figure 8.9: Attach Dome Cap1Thread Sealant or tape2 Dome Cap11. Run a bead of RTV Silicon sealant around the down pipe/Dome Cap interface to seal anyg

Página 102 - Privacy Masks

5 in.12.7 cmmin.Figure 8.10: Pipe Mount1Gasket2 Flange3 Cap1. Before installing the Top-Mounting Flange, ensure there is an adequate opening in

Página 103 - Picture Settings

Wire the Pipe Interface BoardThis section provides instructions for connecting wires and cables to the Pipe Interface Board,as illustrated below. Refe

Página 104

Ref. Description ConnectorWireGaugePin Description1 Pipe InterfaceModule 2 Video Coax In J102 3 6-pin ConnectorAlarms In (3-7)P103 4 4

Página 105

Ref. Description ConnectorWireGaugePin Description1 Dome 24 VAC10 Heater Power P107 AWG18-142 Heater 24 VAC1 Heater 24 VAC11 RJ45 Ethernet J101 1

Página 106 - PTZ Settings

1 4-pin AlarmConnector (P102)2 6-pin Alarm InConnector (P103)3 7-pin Relay Connector (P104)Pin Description Pin Description Pin Description1 Alarm Out

Página 107

Figure 8.13: Pipe Interface Board to Dome Cap Assembly1Interface Board2 Retaining Screws (3)3 Pendant Mounting Screws (2)Attach Pendant to Pipe and Ti

Página 108 - Scenes and Tours

abcFigure 8.14: Pendant to Roof / Pipe Mount Attachment1Tilt Dome2 Hook and drop2a Dome Cap2b Recessed Hinge Pin2c Dome Connector3 Rotate down to enga

Página 109

4. Rotate the dome housing down to a vertical position and gently push upward to engagethe connector on top of the dome housing.!Caution!If you feel a

Página 110

Installing the In-Ceiling MountDescriptionThis chapter details how to install the camera in an In-Ceiling Mount. The In-CeilingAUTODOME camera is suit

Página 111

Safety ENAbout this ManualThis manual has been compiled with great care and the information it contains has beenthoroughly verified. The text was comp

Página 112 - Recording Profiles

Figure 9.2: Cut Hole in Ceiling Tile2. Tighten the four (4) securing screws to the Bracket Assembly.Figure 9.3: Tighten Bracket Securing Screw3. Secur

Página 113 - Maximum Retention Time

Wire the Interface BoxThe Interface Box can be wired through the top or side. Use the supplied rubber plug to sealthe hole which will not be used to r

Página 114 - Recording Status

1 123456234N.O. COM N.C. A1 GND A21 PINPINP102P103P104WHITEORANGEBROWNGREENWHITEORANGEBROWNGREENYELLOWBLUE234567Figure 9.6: Alarm and relay co

Página 115 - Alarm Connections

P105P104P102P103J101J10224VAC24VACP101SIG GNDTXD (-)RXD (+)C +C -NCNOCOMAGNDA2A1J103A3A4A5A6A7AGNDAGNDOUT3OUT2OUT1Figure 9.7: In-ceiling Interface Bo

Página 116

Notice!Pins for P105 1, 2, 4, and 5 are used for audio input and output for AUTODOME 7000 Seriescameras; however, their labels are still those of pre

Página 117

1 2345Figure 9.8: In-ceiling (IP54 Rating) Installation Diagram1White Trim Ring (factory-installed ondome bubble)5 Inner Ring2 Black Trim Ring (suppli

Página 118

Figure 9.9: Attach Housing to Interface Box1. Insert the In-ceiling housing through the hole in the ceiling to verify that the edge of thehole support

Página 119

!Caution!The In-ceiling dome is provided with tether points on each side of the housing. To preventinjury, attach a safety wire from a secure anchor p

Página 120

mminches40 mm1.57 in. MAXIMUM CEILING6.5 mm 0.26 in. MINIMUM CEILINGFigure 9.11: Secure camera to ceiling1 Tether Point 4 Ceiling Clamp2 Ceiling Cla

Página 121 - Audio Alarm

Preparing the BubbleThe inside of the housing may contain packing material to safeguard the camera duringshipping. If so, you must remove the packing

Página 122 - Alarm E-Mail

3. Ventilation - Any openings in the unit enclosure are provided for ventilation to preventoverheating and ensure reliable operation. Do not block or

Página 123 - Alarm Rules

Figure 10.2: Pendant Bubble Release Opening3. Firmly rotate the bubble counterclockwise approximately 20 degrees until the bubbleassembly releases fro

Página 124

Replace the bubble in an in-ceiling housingFigure 10.3: In-Ceiling Bubble1. Use a non-permanent marking instrument (such as chalk or a carpenter penci

Página 125

ConnectionConnecting the AUTODOME camera to the PC1. Install the camera according to the instructions in the appropriate Installation section ofthis m

Página 126

!Caution!Compliance with EN50130-4 Alarm Standard – CCTV for Security ApplicationsTo meet the requirements of the EN50130-4 Alarm Standard, an ancilla

Página 127 - Advanced

!Caution!Ethernet CAT 5E/CAT 6 cables must be routed through earth-grounded conduit for indoor oroutdoor applications. For outdoor applications, the

Página 128 - Network Management

Ethernet Media ConverterMaximum Distance 20 km (12.4 miles)Requirement Media converter receiver (CNFE2MC/IN) at controller end of systemTerminal Conne

Página 129 - Multicast

2.2KFigure 11.2: N.O.S. - Normally Open Supervised Connections1 Dry Contact 3 Dome Connector2 Alarm 1 or 2 only (Pin 5 or 6) 4 Ground (Pin 7)3. From t

Página 130 - Image Posting

Configuring Non-supervised Alarms (inputs 3 through 7)You can configure alarms 3 through 7 as non-supervised Normally Open (N.O.) or NormallyClosed (N

Página 131

Alarm OutputsThe camera incorporates two (2) types of alarm outputs: one dry contact relay and three (3)open collector outputs or transistor outputs.C

Página 132

Shield Bare copper braid: 95% coverageInternal gain level adjustment is available in case the signal level is too low. Wire SpecificationsWire Type Sh

Página 133

an object has fallen into the unit;unit has been dropped or the unit cabinet is damaged;unit exhibits a distinct change in performance;unit does not o

Página 134 - Operation

Notice!Separate the audio cables from the AC power lines to avoid noise.To configure audio on the camera, refer to Basic Mode: Audio, page 87 or Audio

Página 135

ConfigurationSystem RequirementsThe camera requires specific software and hardware to allow a user to view live images and toconfigure camera settings

Página 136

Configuring the CameraTo operate the camera in your network, you must assign a valid network IP address to it. Ifyour network has a DHCP server, the I

Página 137

4. Click the Settings link, located at the top of the LIVE page.5. In the left pane of the window, click Advanced Mode, and then click Network. TheNet

Página 138

8. Click Set and Reboot. The device will reset (go through the homing sequence, whichusually takes 30 seconds to complete), and then the LIVE page app

Página 139

2. Click the Set and Reboot button. The camera reboots and the changed settings areactivated.Configuring Audio (Optional)Enabling Audio TransmissionTo

Página 140 - Figure 15.2: Playback page

Configuration via IP, Basic ModeBasic Mode: Device AccessCamera nameYou can give the camera a name to make it easier to identify. The name makes the t

Página 141

Some changes only take effect after the unit is rebooted. In this case, the Set button changesto Set and Reboot.1. Make the desired changes.2. Click t

Página 142 - Using Intelligent Tracking

Basic Mode: System OverviewThe data on this page are for information purposes only and cannot be changed. Keep arecord of this information in case tec

Página 143 - Operation

Configuration via IP, Advanced ModeAdvanced Mode: GeneralIdentificationCamera nameThe camera name makes it easier to identify the remote camera locati

Página 144

Section 810 of the National Electrical Code, ANSI/NFPA No.70, provides information regardingproper grounding of the mount and supporting structure, gr

Página 145

Notice!Proper password protection is only guaranteed when all higher authorization levels are alsoprotected with a password. If a live password is ass

Página 146 - Troubleshooting

Daylight saving timeThe internal clock can switch automatically between normal and daylight saving time (DST).The unit already contains the data for D

Página 147

Time stampingThis field sets the position of the time overlay. It can be displayed at the Top, at the Bottom orat a position of your choice that you c

Página 148 - Maintenance

Enter the interval (in seconds) between insertions of the digital signature.Advanced Mode: Web InterfaceAppearanceOn this page you can adapt the appea

Página 149 - Maintenance

LIVE FunctionsOn this page you can adapt the functions on the LIVE page to your requirements. You canchoose from a variety of different options for di

Página 150 - Technical data

2. If necessary, click Browse to find a suitable directory.LoggingSave event logCheck this option to save event messages in a text file on your local

Página 151 - User Command Table

!Caution!The camera disables the Privacy Mask function if the orientation is set to Inverted.SC settingsClick the Default button to restore all camera

Página 152

Encoder ProfileFigure 14.1: Advanced Mode>Camera>Encoder Profile>Profile 1 [HD models only]For the video signal encoding, you can select a co

Página 153

Notice!In the default setting, Stream 1 is transmitted for alarm connections and automaticconnections. Keep this fact in mind when assigning the profi

Página 154

Target bit rateTo optimize use of the bandwidth in the network, limit the data rate for the device. The targetdata rate should be set according to the

Comentários a estes Manuais

Sem comentários