GV3 Series v8.11 or Higher Setting Up Points and Outputs | en 15
Bosch Security Systems, Inc. Quick Reference Guide F01U170805 | 02 | 2011.10
To make a custom point index, use Table 6.4 on Page 14 and Table 6.5 on Page 15. For
example, to create an Interior Follower point with a delay on Open and Trouble on Short, use
Point Type 3 and Point Response 5.
Table 6.5 Point Response Selections
NOTICE!
The selections in Table 6.5 indicate:
D = Delayed Response
I = Instant Alarm
S = Supervisory
T = Trouble
Blank = No Response
Point Response
Selections*
0123456789ABCDEF
Armed OpenIIIIDDIIDIIIIIT
ShortIIIIIIDDDI IIIII
Disarmed Open T T T I I T I T
Short T T T I T I I
24-HourOpenITIT ITSTS S N/A
ShortI I TTI T TS SS