Bosch D625 Manual do Utilizador Página 2

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 7
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 1
System overview
7
GND G Y R
SER RXTX BUS RXTX
LED ENABLE
DB9 GND
ENABLE
P1
P5
ON
1 2 3 4 5 6
1 2 4
8
16 M
P2
ON
OFF
1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8
O
N
1 2 3 4
O
N
18 VAC
Data
GRN YEL
- +
Aux/Data
R
Y
G
B
Bat+ Bat-
Alrm
+
PO1
L-1
+
-
L-2Com L-4ComL-3 L-6ComL-5 L-8ComL-7
T
T1
R1
AUXILIAR Y
JP1
Installer
JP2-PO1
Select
Aux Power
-
A B
R
12 VDC
+
PO4
PO3
PO2
ON
1 2 3 4 5 6
+OUT- TMPR R B G Y 1 COM
2 3 CO M 4 5 COM 6 7 CO M 8
4
5
1
3
2
6
3
1
Test
System
Weekly
Test
System
Weekly
8
1
.
D621 Series Keypad (D621, D621W, D621B)
2
.
RF3224 RF Receiver
3
.
D623 or D625 Series Keypad (DD623, D623W, D623B, D625,
D625W, D625B)
The second D623 or D625 Series Keypad shown represents an
installer’s keypad. This keypad is not necessary for programming
or diagnostics.
4
.
D4412 Control Panel
5
.
DX3010 Series Octo-Output Expander
6
.
DX2010 Series Input Expander
7
.
DX3020 X-10 Interface Module
8
.
DX4010i RS-232 Serial Interface Module
Functions
Areas
You can divide the D4412 Control Panel into two
independently configurable areas. Each area has
specific keypads and can have its own account
number.
You can program an automatic arming time for each
area. You can extend the Auto All On time by one hour
(delayed arming).
Outputs
The D4412 Control Panel has four on-board
programmable outputs. You can expand up to 12
outputs.
PO 1: An alarm power output. The default
configuration for PO 1 makes it a dry contact, Normally
Open relay.
PO 2: Use with Alarm + as a supervised speaker driver.
Connect an approved 4 W or 8 W speaker. PO 2 can
sink up to 500 mA, 12 VDC.
PO 3 and 4: Alarm outputs. These outputs can sink up
to 500 mA, 12 VDC each.
Points
The D4412 Control Panel has eight on-board points
and supports hard-wired expanded points and
wireless points up to 24 points. Program any of these
points to follow one of 15 point indexes.
The D4412 Control Panel allows doubled point
configuration using two resistors per sensor loop. The
control panel monitors two points per sensor loop in
the doubled configuration, creating 15 on-board
points. Point doubling is also possible for hard-wired
expanded points.
Notice
On-board Point 1 cannot be doubled.
You can extend delay times for entry or exit points
located a long distance from the keypad.
Multiple Users and Passcodes
The system supports up to 32 passcodes and users.
The passcodes can range between three and seven
digits. The default is four digits.
Programmable from Keypads or from RPS
Program the system using keypads or using RPS. An
installer's keypad feature allows quick access to the
programming menu. RPS is an account management
and control panel-programming utility for the
Microsoft
®
Windows
®
operating system. It is designed
to remotely or locally set up and program specific
control panels.